eSSL C3-100 Review: The Single Door That Answers From Software

C3-100 review: 30,000 holders, 100,000 events, two Wiegand readers and Form-C relays. The one-door panel for the audit-facing door.

Quick answer

C3-100 holds 30,000 card holders with 100,000 events behind two Wiegand readers, with exit and sensor inputs plus Form-C lock and auxiliary relays, on TCP/IP and RS-485. Shortlist it for the single critical door that must answer audits from software. Skip it where the estate needs two or four doors on one panel, or where no network route reaches the door.

By 9 min read
Share:
eSSL C3-100 one-door controller in its aluminium enclosure beside the admin-block door
eSSL C3-100 one-door controller in its aluminium enclosure beside the admin-block door

Key takeaways

  • C3-100 review: 30,000 holders, 100,000 events, two Wiegand readers and Form-C relays. The one-door panel for the audit-facing door.
  • Start With the Door That Must Answer
  • The Panel, Not the Head: Why One Door Gets a Controller
  • Two Readers, Two Inputs, Two Relays: The Door in Full
  • Capacity: 30,000 Holders, 100,000 Events, One Door

A factory admin block in Faridabad ran its main door on a standalone head for three years, and the ritual every audit was identical: the auditor asked for the quarter's entry log, the admin walked to the door with a USB drive, and the month the drive corrupted, the quarter had no answer. The C3-100 ended the ritual by moving the decision off the door and into a panel. Thirty thousand card holders in the controller's memory, a hundred thousand events in its log, two Wiegand readers watching entry and exit, and the quarter's report pulled from the software on the admin's own PC. The auditor's question got the same answer every quarter after that: the export.

This is a field review of the C3-100: a one-door access-control controller with 30,000 card-holder capacity and 100,000 log events, TCP/IP and RS-485 communication, support for two 26-bit Wiegand readers with other reader types upon request, one exit-button input and one door-sensor input, one Form-C relay for the lock and one Form-C auxiliary relay with built-in auxiliary input and output, in a powder-coated aluminium wall-mount enclosure on a recommended 12V DC / 1.5A supply, supported by Access Security System 3.5 with MS Access and MS SQL database support. The family-level functions like anti-passback, interlocking and fire-panel linkage are described at the Door Controller category level and confirmed per model only where the documentation states them, so this review claims for the C3-100 only what its own page publishes. Every number below comes from the verified catalogue. The two-door and four-door siblings in the C3 and InBio families get their own reviews next in this series.

Start With the Door That Must Answer

Three questions settle the C3-100 before you compare prices.

  1. Is this one door critical enough to deserve its own panel, or should it share a two-door or four-door controller?
  2. Do entry and exit both need readers, or does an exit button suffice for the way out?
  3. Does TCP/IP reach the door's position, or must the panel ride RS-485 back to the network?

Single critical doors point here. Estates with paired doors can browse the wider access control family in the meantime, and standalone single doors without audit pressure point at the K30 Pro review. Family context lives in the fingerprint attendance machine guide.

The Panel, Not the Head: Why One Door Gets a Controller

A standalone head makes its decisions at the door and keeps its log at the door; a panel makes its decisions in software and keeps its log where the auditor can reach it. That is the whole C3-100 argument: the 30,000-holder roster lives in Access Security System 3.5 on MS Access or MS SQL, the door's events flow to the same database over TCP/IP or RS-485, and the quarter's report is an export rather than a walk with a USB drive. The powder-coated aluminium enclosure on the wall is the part the visitor sees; the database is the part the auditor meets.

Prove the export during acceptance: pull one quarter-length report from the software with the auditor's own fields on it. The door that proves the export once never walks a USB drive again.

Two Readers, Two Inputs, Two Relays: The Door in Full

Two 26-bit Wiegand readers mean the door watches both directions with proper credentials each way, and other reader types are available upon request for the estate that standardized on something else. The exit-button input and door-sensor input give the way out and the door's honesty their own wires, while the Form-C lock relay drives the strike or magnet and the Form-C auxiliary relay drives the alarm, the hooter or the second device the door's policy names. Built-in auxiliary input and output extend the door's vocabulary without another board.

Commission with the full door proved: one entry read, one exit read, one sensor state visible with the door open, and one auxiliary relay firing on schedule. The relay that was never fired during acceptance is a catalogue line until the month the alarm should have sounded.

Capacity: 30,000 Holders, 100,000 Events, One Door

Thirty thousand card holders is a roster no single door will ever fill, which is exactly the point: the panel never becomes the reason the estate re-enrols, and the same database can serve the door for the building's lifetime without a capacity conversation. A hundred thousand events absorbs a busy single door's entries, exits, sensor states and relay firings through many months before the software's drain keeps it comfortably below half. The 160 x 106 mm board inside the 380 x 80 x 280 mm bundle enclosure at 3.35 kg is the part the wall holds; the MS Access or MS SQL database is the part the auditor holds.

Treat 60,000 stored events as the review line: at that point the named owner confirms the software drains on schedule rather than discovering the buffer the quarter the auditor asks. The door that drains quarterly never owes the auditor a missing month.

Comparison: C3-100 Against the Single-Door Bench

DoorWhere decisions liveHoldersEventsExit side
C3-100Panel + software database30,000100,000Second Wiegand reader
K30 ProStandalone head2,000200,000Two exit readers
F6Standalone reader + panel Wiegand50030,000Exit button interface
MA500Master/slave pair on RS4853,000100,000Slave head on RS485

Specs come from verified catalogue pages; the Where-decisions-live column names what each device publishes for its control architecture. Family context sits in access control beside biometric attendance.

Wiring: Readers, Sensor, Relays and the Two Routes Home

Two Wiegand reader lines land entry and exit, the exit-button and door-sensor inputs land the way out and the door's honesty, and the Form-C lock and auxiliary relays land the strike and the alarm on a recommended 12V DC / 1.5A supply. TCP/IP carries the door's traffic to Access Security System 3.5 while the network holds; RS-485 carries it across the distance the twisted pair was laid for where the switch never reached. Built-in auxiliary input and output extend the door without another board, and the wall-mount aluminium enclosure keeps the board honest through the plant's dust and the corridor's knocks.

Size the door before ordering: panel bundle, two readers in the named Wiegand format, lock, sensor, exit button, auxiliary device, cabling for both routes, and the software licence the 100,000 events drain into. The route that was never landed during acceptance is a paragraph until the month the network cabinet is re-patched.

Software and the Database That Answers Audits

Hardware decides at the door; software answers at the desk, and the C3-100's events reach Access Security System 3.5 over TCP/IP or RS-485 where the 30,000-holder roster, time-wise rules and door-wise policy apply, on MS Access or MS SQL as the product page lists. Demand one quarter-length export in the auditor's own format before the purchase order, generated by whoever answers audits yearly, with entry, exit, sensor and relay events reconciled to one door per day. Other reader types upon request are the estate-standardization conversation to have with the supplier before the readers are ordered, not after.

Access-control buyers study the ONVIF profile guidance for device-integration hygiene where cameras meet the door and the EPFO employer portal for the attendance side of the same export. One evening with both repays itself the first quarter the panel log and the payroll line agree without the USB walk.

Enrolment Playbook: Roster in Software, Cards at the Desk

Day one builds the roster with the admin: the 30,000-holder database seeded from HR's own list, reader formats confirmed against the estate standard, and the exit reader's direction labelled before anyone enrols. Day two issues the first cards at the desk, proves entry and exit reads at the door, and fires the auxiliary relay on schedule with the supervisor watching. Day three pulls the quarter-length export in the auditor's format and trips the door sensor with the door deliberately open. The week closes with the drain schedule set in Access Security System 3.5 before the events ever reach half.

What a Single-Panel Rollout Looks Like

Survey the door for reader positions, lock type, sensor and exit placement, and where TCP/IP or RS-485 lands before ordering. Raise the per-door BOQ with panel bundle, two readers, lock, sensor, exit button, auxiliary device, cabling for both routes, supplies and licences. Install in the labelled enclosure, program door-wise and time-wise rules in software, enrol the roster the week before go-live, and train the admin on exports alongside payroll on the month-end close. Sign AMC after the first audit quarter and one full drain both log cleanly.

Installation Traps We See on Site

  • Family functions assumed per-model. Anti-passback and fire linkage need model-level confirmation in writing.
  • Exit reader skipped. One reader plus a button is a different door; order the pair if both directions matter.
  • Drain never scheduled. A hundred thousand events only help if the software pulls them quarterly.
  • Reader format discovered at the door. Confirm Wiegand or the upon-request type before the readers ship.
  • Aux relay never fired. Prove the auxiliary output on schedule or it stays a catalogue line.

Who Should Buy It: Three Door Profiles

First, the factory admin block whose main door must answer audits from software. The C3-100's database-backed log turns the auditor's quarter into an export instead of a walk with a drive.

Second, the apartment or hospital door that needs both directions credentialed. Two Wiegand readers watch entry and exit properly, with sensor and exit inputs keeping the door honest.

Third, the site with an alarm, hooter or second device the door's policy names. The Form-C auxiliary relay with its own input and output drives it without another board.

Total Cost: The Honest Panel Arithmetic

The panel bundle sits mid-bench, and the honest door adds two readers, lock, sensor, exit button, auxiliary device, cabling for both routes, software licence, enrolment manpower, rule programming and AMC. The savings are structural: the USB walk retires, the auditor's quarter arrives as an export, and the 30,000-holder roster never forces a re-enrolment. Compare cost per door that answers from software, and C3-100 lands where its catalogue position suggests: the single critical door's panel.

Door-count rule for C3-100

Past two doors, one panel with central software costs less than separate boxes. The C3-100 earns its place when leavers vanish everywhere in one click.

Wiring discipline

Label every input pair at survey time. The C3-100 install that photographs terminations never reopens the enclosure.

Software handshake

Confirm card formats and time zones inside the software before mounting. The C3-100 only enforces what the database knows.

A Closing Word You Can Act On

For buyers, confirm per-model functions in writing, order both readers, schedule the drain, and demand the auditor-format export before signing. Next deep dive: the C3-200 for the paired doors that share one panel instead. Tell us your door count, reader standard and audit format for a per-door sizing sheet from verified capacities.

Want the short version of every guide like this?

Get practical buying tips, product comparisons and security advice — plus a free consultation when you're ready to compare options.

C3-100 (C3-100)
View C3-100

C3-100

In Stock

The eSSL C3-100 is a one-door access-control controller supporting up to 30,000 card holders and 100,000 log events. It provides TCP/IP and RS-485 communication, supports two 26-bit Wiegand readers and includes dedicated inputs for an exit button and door sensor, plus lock and auxiliary relay outputs.

  • Card Capacity30,000
  • Auth
  • Standard Connectivity
C3-200 (C3-200)
View C3-200

C3-200

In Stock

The eSSL C3-200 is a two-door access-control panel supporting up to 30,000 card holders and 100,000 log events. It provides TCP/IP and RS-485 communication, supports up to four readers, six inputs and four relay outputs, and is designed for wall-mounted access-control installations.

  • Card Capacity30,000
  • Auth
  • Standard Connectivity

Frequently Asked Questions — eSSL C3-100 Review: The Single Door That Answers From

Pan-India Enterprise Security Engineers

Need help implementing this? — eSSL C3-100 Review: The Single Door That Answers From

Tell us your requirement and our certified security engineers will configure the exact hardware, cloud attendance software, and installation plan — with pan-India AMC warranty.

Genuine Hardware Pan-India Installation 1-Business-Day Quote