C3-400 review: four doors, 12 readers, 30,000 users with confirmed anti-passback, interlock and linkage. The advanced C3 panel.

Quick answer

C3-400 runs four doors with 12 readers and 30,000 users behind 100,000 events, with per-model anti-passback, interlock and linkage, browser monitoring and a 55C operating ceiling. Shortlist it for the four-door floor that must behave as one system. Skip it where two doors would already suffice, or where no network route reaches the panel.

By 10 min read
Share:
eSSL C3-400 four-door panel running a tower floor with interlock between lobby doors
eSSL C3-400 four-door panel running a tower floor with interlock between lobby doors

Key takeaways

  • C3-400 review: four doors, 12 readers, 30,000 users with confirmed anti-passback, interlock and linkage. The advanced C3 panel.
  • Start With the Floor That Must Behave as One
  • Per-Model Functions: Anti-Passback, Interlock and Linkage, Confirmed
  • Twelve Readers, Two Buses: RS-485 Meets Wiegand
  • Capacity: 30,000 Users, 100,000 Events, Four Doors

A commercial tower in Gurgaon runs four doors off one security desk: the lobby turnstile, the lift lobby, the server floor and the terrace exit nobody admits exists. For two years the desk ran them as four separate arguments: two standalone heads, one keypad and a padlock with a register. The C3-400 gave the floor one brain with four doors on it. Twelve readers across RS-485 and Wiegand, twelve inputs watching every exit device and door status, eight relays driving four locks and four alarms, and the interlock rule that finally stopped the lobby and the lift lobby standing open together. The terrace exit got its smoke detector on the auxiliary input the same week. Four doors, one browser window, and the padlock retired to the store room.

This is a field review of the C3-400: a four-door advanced access-control system with 30,000-user capacity and a 100,000-event buffer on a 32-bit MIPS CPU with 32MB RAM and 128MB flash, TCP/IP and RS-485 communication, 12-reader capacity as 8 RS-485 plus 4 26-bit Wiegand interfaces with proximity, MIFARE and HID reader support, 12 inputs as four exit-device plus four door-status plus four auxiliary, 8 outputs as four Form-C lock relays plus four Form-C auxiliary relays, per-model confirmed anti-passback, interlock, linkage, multi-card opening, remote door opening and closing, browser-based real-time monitoring, auxiliary connections for alarms, cameras and door bells, on DC 9.6V to 14.4V at 1A rated maximum, operating 0C to 55C at 10% to 80% relative humidity non-condensing, with Access Security System 3.5 on MS Access and MS SQL. Every number below comes from the verified catalogue. For the two-door panel in the same family, read the C3-200 review.

Start With the Floor That Must Behave as One

Three questions settle the C3-400 before you compare prices.

  1. Do these four doors share people and policy, so interlock and anti-passback between them are load-bearing rather than decorative?
  2. Which reader technology does the estate standardize: proximity, MIFARE or HID, and does the order name it?
  3. Does the floor need multi-card opening or remote open/close for any door, and is that rule written before commissioning?

Four-door floors with shared policy point here. Paired doors point at the C3-200 review, and single critical doors point at the C3-100 review. Family context lives in the access control category beside biometric attendance.

Per-Model Functions: Anti-Passback, Interlock and Linkage, Confirmed

This is where the C3-400 earns its "advanced" product type in writing: anti-passback, interlock, linkage, multi-card opening and remote door opening/closing are confirmed at the model level on the current page, not merely described at the family level. Anti-passback refuses the tailgate that walks the lobby on someone else's card; interlock stops the lobby and lift lobby standing open together; linkage lets one event drive another device's relay; multi-card opening demands two credentials where the policy names it; remote open/close gives the security desk its browser button. Browser-based real-time monitoring is the window the desk watches all of it through.

Prove each rule during acceptance with the supervisor watching: one refused tailgate, one refused double-open, one linkage firing, one two-card opening and one remote open from the browser. The rule that was never proved is a catalogue line until the month it should have fired.

Twelve Readers, Two Buses: RS-485 Meets Wiegand

Eight RS-485 readers plus four Wiegand readers is the floor's reader budget in one panel: the long RS-485 runs reach the far doors without a switch at each one, while the four Wiegand interfaces keep the estate's standard readers in the family. Proximity, MIFARE and HID support is named on the page, so the order states the technology instead of discovering it at the door. Twelve inputs watch four exit devices, four door statuses and four auxiliary devices independently; eight relays drive four locks and four auxiliary outputs to alarms, cameras and door bells.

Map readers to doors to buses on paper before the first conduit run: which four doors, which readers on RS-485, which on Wiegand, and which technology on each. The bus that was planned on paper lands on schedule; the one remembered later lands nowhere.

Capacity: 30,000 Users, 100,000 Events, Four Doors

Thirty thousand users across four doors is a roster the floor will never outgrow, and the 32-bit MIPS CPU with 32MB RAM and 128MB flash is the engine the page names behind it. A hundred thousand events absorbs four doors' entries, exits, sensor states, detector contacts and relay firings through many months, with the software's quarterly drain keeping the buffer comfortably below half. DC 9.6V to 14.4V at 1A rated maximum is a wider supply window than the smaller panels, and the 0C to 55C operating ceiling with 10% to 80% humidity covers the terrace-adjacent panel room the tower forgot to cool.

Treat 60,000 stored events as the review line: at that point the named owner confirms the software drains on schedule rather than discovering the buffer the quarter the auditor asks. The floor that drains quarterly never owes the auditor a missing month from any of its four doors.

Comparison: C3-400 Against the Multi-Door Bench

PanelDoorsReadersInputs / outputsNamed per-model rules
C3-400412 (8 RS-485 + 4 Wiegand)12 in / 8 outAnti-passback, interlock, linkage
C3-20024 Wiegand6 in / 4 outFamily-level only
C3-10012 Wiegand2 in / 2 outFamily-level only
MA5001 pair on RS485Master/slaveLock, sensor, exit, alarmAnti-passback on the pair

Specs come from verified catalogue pages; the Named-rules column repeats only the functions each model page states in its own words. Family context sits in access control beside biometric attendance.

Wiring: Four Locks, Four Auxiliaries, Two Routes Home

Four exit-device inputs, four door-status inputs and four auxiliary inputs land every wire the floor's four doors own, with the auxiliaries documented for infrared body detectors, fire alarms and smoke detectors. Four Form-C lock relays drive the four strikes or magnets; four Form-C auxiliary relays drive the hooters, camera triggers and door bells the policy names. TCP/IP carries the floor's traffic to Access Security System 3.5 while the network holds; RS-485 carries the far doors and the far readers across the distance the twisted pair was laid for. Size the DC supply inside its 9.6V to 14.4V window with all four locks' draw in the calculation, not after.

Commission with the full floor proved: one entry-exit pair per door, one interlock refusal, one anti-passback refusal, one detector contact firing, and one auxiliary output driving its alarm. The relay that was never fired during acceptance is a catalogue line until the month the floor needed it.

Software and the Four-Door Export

Hardware decides at the doors; software answers at the desk, and the C3-400's events reach Access Security System 3.5 over TCP/IP or RS-485 where the shared 30,000-user roster, door-wise rules, time-wise policy and the confirmed interlock tables apply, on MS Access or MS SQL as the product page lists, with the roster syncing from hrms on the schedule the admin sets. Browser-based real-time monitoring gives the security desk its live window without a second application. Demand one quarter-length export covering all four doors in the auditor's own format before the purchase order, generated by whoever answers audits yearly, with entry, exit, sensor, detector, interlock and relay events reconciled per door per day.

Access-control buyers study the ONVIF profile guidance for device-integration hygiene where cameras meet the doors and the EPFO employer portal for the attendance side of the same export. One evening with both repays itself the first quarter the floor's log and the payroll line agree without the padlock's register.

Enrolment Playbook: One Roster, Four Doors, Written Rules

Day one builds the roster with the admin: the shared 30,000-user database seeded from HR's own list, reader technologies named per door, and the interlock pairs and multi-card doors written as rules before anyone enrols. Day two issues the first cards at the desk, proves entry and exit reads on all four doors, and fires every auxiliary relay on schedule with the supervisor watching the browser window. Day three proves each confirmed rule deliberately, pulls the four-door quarter export in the auditor's format, and trips one detector contact to read. The week closes with the drain schedule set in Access Security System 3.5 before the events ever reach half.

What a Four-Door Rollout Looks Like

Survey all four doors for reader positions and buses, lock types, sensor and exit placement, detector positions, and where TCP/IP or RS-485 lands before ordering. Raise the per-floor BOQ with panel, twelve readers in named technologies, four locks, sensors, exit devices, named detectors, alarms, camera triggers and door bells, cabling for both routes, supplies and licences. Install in the labelled enclosure, program shared roster with door-wise rules and interlock tables in software, enrol the roster the fortnight before go-live, and train the security desk on the browser window alongside payroll on the month-end close. Sign AMC after the first audit quarter and one full drain both log cleanly.

Installation Traps We See on Site

  • Reader buses unmapped. Eight RS-485 plus four Wiegand needs a paper map before conduit, not after.
  • Rules unwritten. Interlock pairs and multi-card doors must be specified before commissioning, not discovered.
  • Power sized for the panel alone. Add all four locks' draw inside the 9.6V to 14.4V window.
  • Detector contacts unnamed. Four auxiliary inputs need named devices with contact types on the BOQ.
  • Drain never scheduled. A hundred thousand events across four doors only help if the software pulls them quarterly.

Who Should Buy It: Three Four-Door Profiles

First, the commercial tower floor whose four doors must behave as one system. The C3-400's confirmed interlock, anti-passback and linkage turn four arguments into one policy with one browser window.

Second, the site with detectors waiting for a panel across multiple doors. Four auxiliary inputs take the smoke, IR and fire contacts the floors already own, and four auxiliary relays answer with alarms and cameras.

Third, the estate mixing reader buses and technologies. Eight RS-485 plus four Wiegand interfaces with proximity, MIFARE and HID support keep the long runs and the standard readers in one panel.

Total Cost: The Honest Floor Arithmetic

The panel sits at the top of the C3 bench, and the honest floor adds twelve readers in named technologies, four locks, sensors, exit devices, named detectors, alarms, camera triggers and door bells, cabling for both routes, software licence, enrolment manpower, rule programming and AMC. The savings are structural: one roster replaces four enrollments, one export replaces four walks, and the interlock replaces the guard posted between two doors that kept opening together. Compare cost per floor that behaves as one system, and C3-400 lands where its catalogue position suggests: the four-door advanced panel.

Door-count rule for C3-400

Past two doors, one panel with central software costs less than separate boxes. The C3-400 earns its place when leavers vanish everywhere in one click.

Wiring discipline

Label every input pair at survey time. The C3-400 install that photographs terminations never reopens the enclosure.

Software handshake

Confirm card formats and time zones inside the software before mounting. The C3-400 only enforces what the database knows.

A Closing Word You Can Act On

Write the rules before enrolment, map every reader to its bus, size power with all four locks, and demand the four-door auditor export with one proved rule per function before signing. Next deep dive: the InBio260 for the estate that wants fingerprints at the panel instead of cards alone. Tell us your door count, rule list and reader standard for a per-floor sizing sheet from verified capacities.

Want the short version of every guide like this?

Get practical buying tips, product comparisons and security advice — plus a free consultation when you're ready to compare options.

C3-400 (C3-400)
View C3-400

C3-400

In Stock

The eSSL C3-400 is a four-door access-control system supporting 30,000 users and a 100,000-event buffer. It provides TCP/IP and RS-485 communication, supports up to 12 readers through RS-485 and Wiegand interfaces, and offers 12 inputs and 8 relay outputs.

  • Auth
  • Standard Connectivity
C3-200 (C3-200)
View C3-200

C3-200

In Stock

The eSSL C3-200 is a two-door access-control panel supporting up to 30,000 card holders and 100,000 log events. It provides TCP/IP and RS-485 communication, supports up to four readers, six inputs and four relay outputs, and is designed for wall-mounted access-control installations.

  • Card Capacity30,000
  • Auth
  • Standard Connectivity

Frequently Asked Questions — eSSL C3-400 Review: Four Doors, One Brain, Rules in

Pan-India Enterprise Security Engineers

Need help implementing this? — eSSL C3-400 Review: Four Doors, One Brain, Rules in

Tell us your requirement and our certified security engineers will configure the exact hardware, cloud attendance software, and installation plan — with pan-India AMC warranty.

Genuine Hardware Pan-India Installation 1-Business-Day Quote