eSSL Vehicle Control in India: Boom Barriers, Gates & Bollards
44 eSSL vehicle models compared: 11 booms, 5 sliding motors, UHF plus ANPR plus tyre killers. A boom lane without loop plus photocell is a lawsuit.
Quick answer
eSSL Vehicle Control — eSSL vehicle guide India: 44 models — boom barriers, sliding motors, gate openers, UHF, ANPR. Loop plus photocell safety is no. eSSL vehicle control models comp

Key takeaways
- 44 eSSL vehicle models compared: 11 booms, 5 sliding motors, UHF plus ANPR plus tyre killers. A boom lane without loop plus photocell is a lawsuit.
- Start With Traffic, Not the Barrier
- Boom Barriers: the Lane Workhorses
- Barrier Accessories: the Half Buyers Skip
- Sliding Gate Motors: Heavy Leaves, Daily Cycles
This eSSL Vehicle Control guide starts from the site problem it solves, with verified specs, install notes and sizing for Indian buyers.
A housing society in Noida bought a boom barrier online because the arm length matched the gate. Nobody ordered the loop detector. Within a fortnight the arm dropped on a WagonR bonnet. This eSSL Vehicle Control guide starts from that RWA meeting, not the arm length.
Use this guide to match eSSL vehicle hardware to your traffic, your arm length and your power backup. Every model below comes from the verified catalogue. Each band tells you which lane it controls and which accessory it cannot live without.
Start With Traffic, Not the Barrier
Four questions pick the hardware before you compare arms.
- How many vehicles in the peak hour: 30 residents or 300 trucks?
- What opens the lane: guard button, UHF tag, ANPR plate or all three?
- What stops a hostile vehicle: arm, bollard, tyre killer or fencing?
- What happens in a power cut: arm rises, gate freezes or battery takes over?
Resident lanes want fast arms with UHF. Factory gates want heavy motors with guards. High-risk sites want bollards plus killers behind the arm. Every lane wants backup power decided on paper, not during the first outage.
Boom Barriers: the Lane Workhorses
Arms that rise on authorisation and fall on presence logic. Eleven units cover societies to tolls.
BG-DBC-RL-100: the network flagship
The BG-DBC-RL-100 runs a noiseless DC brushless motor with non-spring architecture, adjustable 1.5 to 6 second arms, auto-reverse on obstacle detection, swing-out arm protection, infrared plus loop-detector anti-smash interfaces, optional backup battery, RS485 plus relay plus count-mode outputs, and RFID plus push-button plus remote integration. This is the lane for IT parks and malls where the barrier talks to parking software and every passage counts. Wire the loop detector and photo cell on day one; auto-reverse needs its eyes.
BG-DC-101 and BG180-BDC: the society pair
Also in this band, the BG-DC-101 and BG180-BDC run 24V DC brushless motors in IP54 housings (348 by 248 by 1060 mm) with 6 m, 4 m and 3 m arm options for societies, offices and schools. Pick the arm by lane width minus half a metre of clearance, not by the widest option in the list. A 6 m arm on a 4 m lane swings into the guard cabin wall.
BG100 TI and BG100 TII: the toll-grade pair
The BG100 TI and BG100 TII cover high-cycle toll and parking lanes where the arm moves thousands of times a day. Mechanism life matters more than arm speed here. Keep a spare arm and spring set on site; a toll lane down on Monday morning queues to the highway.
BG-100 Grey, BG-108 and BG-S-105: the estate bench
Also in this band, the BG-100 Grey, BG-108 and BG-S-105 extend the BG bench across finishes and housing sizes for estates, clubs and campuses matching gate aesthetics. Pick by housing footprint and arm stock; the lane logic matches. Grey housings hide dust between washes, which matters more than brochures admit.
BG-SC-300, BGL-100 and BG-CM-300: the special lanes
The BG-SC-300, BGL-100 and BG-CM-300 cover short-lane, long-housing and counterweight layouts for basements, split lanes and retrofit plinths. Measure the plinth before ordering; a long housing on a short plinth overhangs into the pedestrian path. a long housing on a short plinth overhangs into the pedestrian path.
BB-Radar: the eyes of the lane
Also in this band, the BB-Radar watches the lane on 79GHz with 1 to 6 m adjustable detection (default 3 m), 9 to 24VDC power, minus 40 to 85C operation and IP66 protection in a 107.9 by 73.6 by 17.2 mm head. It detects vehicle presence where loops cannot be cut, on paver blocks and rented floors. Use radar plus loop together on critical lanes; two eyes beat one in rain.
Barrier Accessories: the Half Buyers Skip
A barrier without safety accessories is a quotation, not a lane. Six units complete every boom.
PSA02 Loop Detectors: the presence proof
The Loop Detector PSA02 and PSA02-2 sense metal mass over the cut loop and hold the arm up while a car sits beneath. No loop, no proof, and the arm timer decides alone. Cut the loop to the lane drawing, seal it against water, and test with a scooter as well as a car; small metal mass fools weak tuning.
PSA26 and PSA122 Photo Cells: the anti-smash beam
Also in this band, the Photo Cell PSA26 wires its beam across the lane while the Wireless Photo Cell PSA122 spans it without trenching. A broken beam holds or reopens the arm. Align the heads at bumper height on both posts and clean the lenses monthly; dusty lenses blind beams by Diwali.
SW01 Push Button and P-PB-Remote: guard control
The Push Button Switch SW01 gives the guard a wired open-close-stop station while the Boom Barrier Remote P-PB-Remote adds wireless control from the cabin. Wire the push button even on automated lanes; remotes lose charge and UHF misses unreadable plates exactly when the queue builds.
> Tip: commission every boom lane with the scooter test. Drive a scooter, a hatchback and an SUV through ten cycles each before handover. Scooters expose loop-tuning gaps, SUVs expose beam-height gaps, and the tenth cycle exposes timer arrogance. Sign the handover only after all thirty pass. Sign the handover only after all thirty pass.
Sliding Gate Motors: Heavy Leaves, Daily Cycles
Sliding gates carry tonnes on rails; motors must match weight plus wind plus grit.
HG-BDC-600 and HG-BDC-800: the estate pair
The HG-BDC-600 and HG-BDC-800 drive society and office sliding leaves with brushless DC control for quiet starts and soft stops. Size by leaf weight with a 30 percent margin for monsoon grit on the rail. A motor at its rated limit stalls exactly when the track floods.
eSSL-HG-1500 and HG-2000: the industrial pair
Also in this band, the eSSL-HG-1500 and HG-2000 move factory leaves with heavier torque and duty cycles for three-shift gates. HG-2000 takes the main plant gate; HG-1500 covers secondary and store gates. Weld the rack in straight runs and level the rail before blaming the motor for judder.
HG-BDC-1200: the heavy-mid bridge
The HG-BDC-1200 bridges estates and industry for large residential towers and warehouses with long heavy leaves. It suits the 8 m society gate that the estate pair cannot start on a slope. Check the slope with a level; gates that roll shut by gravity need brakes, not just motors.
Sliding accessories: racks, lamps and rails
Also in this band, the SR-1000 rack series in 30 by 8 and 30 by 10 sections (SR-10003010) meshes with the pinion for drive, while the PSA27 Alarm Lamp flashes during motion so pedestrians clear the track. Buy racks by leaf length plus one spare metre; cut teeth cannot be uncut when the measurement falls short.
Swing and Shutter Openers: GO and SH Series
Hinged gates and rolling shutters need their own drives.
GO-O-03, GO-O-19 and GO-O-29: the swing trio
The GO-O-03, GO-O-19 and GO-O-29 swing hinged leaves for villas, farmhouses and small offices, with GO-I-28 covering the in-gate variant. Match the opener to leaf weight and wind area; a jaali-design leaf catches monsoon wind like a sail. Gate stoppers decide where the leaf rests, not the motor; fit them before commissioning.
SH-GT and SH-JMT: the shutter drives
Also in this band, the SH-GT3.50-ZM, SH-JMT40, SH-GT5.75-ZM and SH-GT16DC roll shop and godown shutters from 3.5 m to heavy 16DC duty. Size by shutter area and daily cycles; a shutter that opens fifty times a day needs the heavy drive, not the shop variant. Keep the manual chain reachable; power cuts do not respect opening hours. power cuts do not respect opening hours.
UHF and ANPR: Hands-Free Lanes
Tags for staff, plates for visitors, guards for exceptions.
U12-I, U5 and U-10: the tag lane
The U12-I and U5 windscreen tags talk to the U-10 UHF Reader at 5 to 8 metres for hands-free boom opening. Issue tags to residents and staff fleets, mount the reader head at windscreen height on the entry side, and angle it down the lane. Test with the slowest scooter and the tallest SUV; read zones vary by vehicle metal.
LPR 100: the plate lane
Also in this band, the eSSL LPR 100 ANPR Camera reads number plates for visitors, taxis and trucks without tags. Feed its reads into visitor management with entry photos for the gate log. Clean the camera housing fortnightly; number-plate reads die of dust before electronics. Combine tags for staff with ANPR for guests on the same lane; one lane, two credentials, zero guard typing.
| Vehicle family | Models | Lane fit | Best fit | Watch out for |
|---|---|---|---|---|
| Boom BG | DBC-RL-100 to CM-300 | 3-6 m arms | Societies, parks, tolls | Loop plus photo cell mandatory |
| Radar | BB-Radar | 1-6 m zone | Paver and rented lanes | Pair with loop on critical lanes |
| Boom accessories | PSA02, PSA26, PSA122, SW01, remote | Per lane | Every boom | Scooter test before handover |
| Sliding HG | 600 to 2000 | By leaf weight | Estates, factories | 30 percent grit margin |
| Swing GO | O-03 to I-28 | Hinged leaves | Villas, farmhouses | Wind area plus stoppers |
| Shutter SH | GT to JMT40 | By shutter area | Shops, godowns | Manual chain reachable |
| UHF | U12-I, U5, U-10 | 5-8 m reads | Staff fleets | Mount at windscreen height |
| ANPR | LPR 100 | Plate reads | Visitors, trucks | Fortnightly cleaning |
| Bollards | HB-426, RB-219 | Hostile stop | Critical sites | Civil plus electrical project |
| Tyre killers | TK-300 to TK-600 | One-way deny | High-risk entries | Fencing completes the trap |
Bollards and Tyre Killers: the Hostile Stop
Arms manage traffic; steel stops attackers. Six units cover hostile-vehicle mitigation.
HB-426 and RB-219: the rising steel
The HBC-600 Hydraulic Bollard Controller drives hydraulic bollard banks while the HB-426 and RB-219 rise from the road to block hostile vehicles at campuses, malls and critical sites. These are civil-plus-electrical projects: foundation pits, drainage, hydraulics, power and control logic. Order the civil drawings before the bollards; steel without foundation is garden art.
TK-300, TK-400 and TK-600: the one-way deny
Also in this band, the TK-300, TK-400 and TK-600 shred tyres of wrong-way vehicles at exit lanes and high-risk entries. Pair with signage, lighting and fencing that forces the approach line; a killer without channelisation gets straddled by wide-track vehicles. Test with the guard team watching so the response drill exists before the first real attempt.
> Warning: never install tyre killers or bollards without a written traffic plan signed by the site head. Steel that stops attackers also stops ambulances, fire tenders and the chairman's car when the logic misfires. Define the emergency override, guard it with a key switch, test it monthly, and log every test. The override is the system; the steel is just the muscle. the steel is just the muscle.
Power Backup and the First Outage
Every vehicle lane needs its power-failure behaviour on paper. Boom arms fail open or stay shut per spring and battery choice; sliding gates freeze mid-track without backup; bollards stay up or sink per hydraulic logic. Fit the optional barrier battery, a UPS for the lane controller and reader, and a manual release the guard can actually operate. Run the blackout drill before handover: cut mains power, watch each lane behave, time the generator takeover. A lane whose failure mode is discovered during a real outage is a news story.
Visitor Link and Gate Reports
Vehicle reads are visitor data waiting to be used. UHF tags reconcile staff cars with attendance software; ANPR plates plus guard entries flow into visitor management with photos. Demand one combined vehicle-plus-visitor-plus-attendance report in trials. Related ranges live in boom barriers, sliding gate motors, tyre killers and bollards. For pedestrian entries see the entrance pillar.
Mistakes That Waste the Vehicle Budget
Barrier without loop and beam. Timer-only arms drop on bonnets. Presence proof first.
Motor at rated limit. Monsoon grit stalls exact-fit motors. Keep 30 percent margin.
ANPR without cleaning. Dust blinds plates before electronics age. Fortnightly wipe.
Steel without a traffic plan. Bollards stop friends as dead as foes. Override in writing.
For context on lane safety practice, the eSSL Vehicle Control follows the ISO quality management overview, with incident logs aligned to site SOP.
A Closing Word You Can Act On
Count peak vehicles, pick the arm by lane width, complete every boom with loop plus beam, size motors with grit margin, and drill the blackout before handover. Next in this series: the inspection pillar with DFMD gates, baggage scanners and hotel plus safe locks. Tell us your lane width, traffic and power backup for a one-lane shortlist from verified models.
Photograph the door, the power point and the queue before you shortlist the eSSL Vehicle Control. Those three eSSL Vehicle Control site photos settle more arguments than any brochure.
Every figure in this eSSL boom barrier gate review comes from the verified catalogue. Share gate count and headcount for a eSSL boom barrier gate shortlist from MegaMind.
Want the short version of every guide like this?
Get practical buying tips, product comparisons and security advice — plus a free consultation when you're ready to compare options.
Related Products — eSSL Vehicle Control in India: Boom Barriers, Gates & Bollards

BG-DBC-RL-100
eSSL BG-DBC-RL-100 — a boom barrier with network connected, supplied, installed and supported by MegaMind Technosoft across India.
- Auth
- Standard Connectivity

BG-DC-101
eSSL BG-DC-101 is an automatic electromechanical boom barrier using a 24V DC brushless motor. eSSL publishes boom-arm options of 6 m, 4 m and 3 m, corresponding to listed operating speeds of 6 seconds, 3 seconds and 1.5 seconds respectively, with IP54 outdoor protection and loop-detector, radar, photocell and access-controller interfaces.
- Auth
- Standard Connectivity
Keep Reading — eSSL Vehicle Control in India: Boom Barriers, Gates & Bollards
eSSL Entrance Control in India: Turnstiles, Flap & Swing Barriers
Oct 13, 2026 · 9 min read
eSSL Access Control Systems in India: Controllers, Terminals & Readers
Oct 12, 2026 · 9 min read
Access Control Systems: The Complete Buyers Guide for Offices & Campuses
Sep 16, 2026 · 8 min read